Select Language
S. No.
|
PARTICULAR
|
DETAIL
|
---|---|---|
1
|
Sam le Size -
|
5Mtr * 3Duct + 1.5Mtr*3 Duct
|
2
|
Grade variety/type/size/class
|
HDPE PLB DUCT 40mm/33mm
|
3
|
Batch Number
|
202406260091
|
4
|
Marking on pipe
|
SUDARSHAN HDPE PLB DUCT PIPE 50mm/42mm 006 220521
|
5
|
Raw Material Used
|
PE-63 , Blue Master Batch, Silicon, White Master Batch, UV Master batch
|
6
|
Date of initiation
|
01.07.2024
|
7
|
Date of Completion
|
10.07.2024
|
8
|
An Other Information
|
Colour Of Duct-Blue
|
GEOMETRICAL CHARACTERISTICS & DIMENSIONS OF PIPE
S. No.
|
Characteristic
|
Unit
|
Test Cl. No.
|
Test Method
|
Specified Requirement
|
Observed Value
|
---|---|---|---|---|---|---|
1
|
Visual Appearance
|
|
Table-3
|
TEC/GR/FNCDS - 008/04/AUG-19
|
The internal & External-surface of the pipe shall be smooth, clean & free from oovin & other defects.
|
Satisfactory
|
2
|
Length of Duct/Coil
|
M tr
|
4.3 Table3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
|
|
3
|
Colour of Duct
|
|
4.2.1
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Shall be Blue
|
Blue
|
4
|
Colour of Inner Layer
|
|
4.2.7
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Shall be White
|
White
|
5
|
Colour of Strip
|
|
424
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Approximately 4
|
4
|
6
|
No. Of Strip
|
Numbers
|
4 2.3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Approximately 4
|
4
|
7
|
Width Of strip
|
mm
|
42.3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Min. 3.0
|
3.15
|
8
|
Outside Diameter
|
mm
|
4.3 Table3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Min. 40.00 / Max. 40 40
|
40.10 / 40.25
|
9
|
Inner Layer Thickness
|
mm
|
4.3 Table3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Min. 0.28 / Max. 0.42
|
0.34 / 0.39
|
10
|
Ovality
|
mm
|
Table-4
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Max. 1.4
|
055
|
11
|
Wall Thickness
|
mm
|
mm4.3 Table3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Min. 3.3 / Max. 35
|
3 38 / 345
|
12
|
Maximum outer diameter of 'cal Fibre cable
|
mm
|
4.3 Table3
|
TEC/GR/FA/CDS -008/04/AUG-19
|
Max. 16 mm
|
|
Test Result as per GR No : TEC/GWFA/CDS-008/04/AUG-19
PERFORMANCE REQUIREMENTS
S. No.
|
Parameter
|
Unit
|
Test Cl. No.
|
Test Method
|
Specified Requirement
|
Observed Value
|
Remark
|
---|---|---|---|---|---|---|---|
Il draulic Characteristics Of Duct
|
|||||||
Internal Pressure creep rupture test:
|
|||||||
a
|
Test Duratton.48hr Test Temp-800C
|
|
8.1 1, Table-5 Of 4984 2016
|
IS-4984 2016 & Table-5 or TEC/GWFA/CDS008/04/AUG-19
|
Pipe shall show no Sign of localized swelling leakage or weeping and shall not burst durtng prescribed test duration (Induced Stress as per Table-5 Of TEC/GWFAJCDS-OOW04/AUG-19
|
No sign of failure Confirmed
|
Result Pass/fail
|
b
|
Test Duration- 165hr Test Temp.800C
|
|
81 1. Table-5 Of 4984 2016
|
IS-4984 2016 & Table-5 or TEC/GWFA/CDS008/04/AUG-19
|
Pipe shall show no Sign of localized swelling leakage or weeping and shall not burst during prescribed test duration (Induced Stress as per Table-5 or TEC/GWFA/CDS-008/04/AUG-19
|
No Sign of failure Confirmed
|
Result Pass/fail
|
2. Acceptance Test On Duct
|
|||||||
a
|
Optional pre-installed
|
|
|
TEC/GWFA/CDS008/04/AUG-19
|
Duct sue -32,Q6mm, 40/33mm SO/42mm requirement -4mm dta ,2% slackness Duct Stze-63/50mm , 110/80mm utrement-6mm dia
|
|
|
b
|
Tensile Strength & Elongation
|
N/mm2
|
|
ASTM F2160 & ASTM 638
|
Tensile strength at yield —run-20N/mm2 Elongation — Min-500%
|
>23.5N/mm2 > 907 4%
|
|
c
|
Longitudinal Reversion Test
|
|
8 2 Annex
|
IS-4984 2016
|
Shall not change more than 3% in the longitudinal direction
|
Max-2 05
|
|
d
|
Environmental Stress Crack Resistance
|
|
|
ASTM -1693
|
There shall be no failure/crack
|
No Crack Observed - Pass, ‘fail
|
IGEPAL
|
e
|
Impact Strength
|
|
|
IS-12235 . Pt-9
|
The duct shall not crack or split
|
No crack observed
|
Result- Pass/fail
|
f
|
Crush Resistant
|
|
|
TEC/GWFAiCDS008/04/AUG-19
|
The deflecuon With load on and after recovery penod(5min) shall not exceed & 2% Respectively
|
Deflection with loadDeflection after recovery penod
|
|
g
|
Mandrel Test
|
|
CL-4 10
|
TEC/GR,'FA/CDS008/04/AUG-19
|
150mm long mandrel of dia 3mm less than the Internal dia of duct shall be passed through a 5meter length of Duct freely throughout the length, when the duct IS bent to a radius of 5Meter
|
Satisfactory
|
Result Pass/fail
|
h
|
Coil set
|
|
|
|
When a nummum length of 50 meters Duct taken from the coil and laid on the ground , It shall be straight without any bends or kinks and Without deformation ex 5meter from each end
|
Satisfactory
|
|
i
|
Wall ThicknesOxidation Induction Test s
|
M in
|
4.13 , Annex- I
|
TEC/GWFA/CDS008/04/AUG-19
|
Shall not Less Than 30 Minute
|
26
|
DSC Result
|
j
|
Internal Co-efficient of fnctvon
|
|
4 15, Annex-2
|
TEC/GWFA/CDS008/04/AUG-19
|
a) For Nylon Jacketed unarmoured OFC • 006 Max For HDPE PLB Ducts b) For HDPE Jacketed Unarmoured OFC 020Max For HDPE PLB Ducts |
0.168
|
(For HDPE Jacketed Unarmoure d OFC
|
k
|
Optical Fibre Cable blow Ing test
|
|
4 17
|
TEC/GWFA,'CDS008/04/AUG-19
|
It shall Possible to blow in the Optical through the I km duct each time tn not more than 35min
|
|
|
WhatsApp us