SUDARSHAN MDPE PIPES AS PER ISO : 4427 - 2 - 2007
|
|||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DIMENSIONAL CHART OF POLYTHENE PIPES AS PER ISO 4427 - 2 : 2007
|
|||||||||||||||||||
Pope Series[S=(SDR-1)/2]
|
6.3
|
5
|
4
|
3.2
|
2.5
|
||||||||||||||
|
1
|
11
|
|
|
|
||||||||||||||
PE 80
|
PN 10
|
PN 12.5
|
PN 16
|
PN 20
|
PN 25
|
||||||||||||||
PE 100
|
PE 12.5
|
PE 16
|
PE 20
|
PE 25
|
|
||||||||||||||
OD-Min
|
OD-Max
|
OD-Min
|
OD-Max
|
OD-Min
|
OD-Max
|
OD-Min
|
OD-Max
|
OD-Min
|
OD-Max
|
OD-Min
|
OD-Max
|
||||||||
16
|
16.3
|
|
|
|
|
2
|
2.3
|
2.3
|
2.7
|
3
|
3.4
|
||||||||
20
|
20.3
|
|
|
2
|
2.3
|
2.3
|
2.7
|
3
|
3.4
|
3.4
|
3.9
|
||||||||
25
|
25.3
|
2
|
2.3
|
2.3
|
2.7
|
3
|
3.4
|
3.5
|
4
|
4.2
|
4.8
|
||||||||
32
|
32.3
|
2.4
|
2.8
|
3
|
3.4
|
3.6
|
4.1
|
4.4
|
5
|
5.4
|
6.1
|
||||||||
40
|
40.4
|
3
|
3.5
|
3.7
|
4.2
|
4.5
|
5.1
|
5.5
|
6.2
|
6.7
|
7.5
|
||||||||
50
|
50.4
|
3.7
|
4.2
|
4.6
|
5.2
|
5.6
|
6.3
|
6.9
|
7.7
|
8.3
|
9.3
|
||||||||
63
|
63.4
|
4.7
|
5.3
|
5.8
|
6.5
|
7.1
|
8
|
8.6
|
9.6
|
10.5
|
11.7
|
||||||||
75
|
75.5
|
5.6
|
6.3
|
6.8
|
7.6
|
8.4
|
9.4
|
10.3
|
11.5
|
12.5
|
13.9
|
1
|
Visual Appearance
|
Visual
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019 CL-5.1
|
---|---|---|---|---|
2
|
Colour of Pipe
|
Visual
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019, CL 5.2 Annex-A , The pipe shall be either blue or Black with blue strip.
|
3
|
Wall Thickness
|
Measurement
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019 CL-6.3 Table-2
|
4
|
Outer Diameter
|
Measurement
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019 Cl-6.1 Table-1
|
5
|
Ovality
|
Measurement
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019 CL-6.2 Table-1
|
6
|
Length of the Pipes
|
Measurement
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019 CL-6.5 , As per Customer Requirement. (200/500 Mtr)
|
7
|
Coiled Pipes
|
Measurement
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As Per ISO-4427-2-2019 CL-6.4 The pipe shall be coiled such that localized deformation eg. buckling and kinking, is prevented. The minimum internal diameter of the coil shall be not less than 18Dn
|
8
|
Marking & Identification
|
Visual
|
Sampling shall be done as per IS 4984-2016 Table 9 As Per ISO-4427-2-2019
|
As per ISO4427 CL-12 Each pipe shall have at minimum marking of: (a) Manufacturer Name/Trade Mark (b) Material Designation (c ) SDR (d) Outside Dia meter (e) Batch Number |
9
|
Longitudinal Reversion Test
|
Hot Air Oven Method
|
ISO 4427-2 2019 Table-5 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
Shall not be more than 3%; No effect on the surface
|
10
|
Melt Flow rate at 190 °C / 5 Kg
|
Melt Flow
|
ISO 4427-2 2019 Table-5 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
Maximum deviation of 20% of the Nominated value
|
11
|
Density at 27% (Base Density)
|
Density
|
ISO 4427-2 2019 Table-5 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
≥ 930 Kg/m3
|
12
|
Oxidation Induction Time (OIT)
|
OIT Test
|
ISO 4427-2 2019 Table-5 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
> 20 minutes
|
13
|
Elongation at Break
|
Tensile Test
|
ISO 4427-2 2019 Table-5 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
≥ 350%
|
14
|
Internal Pressure Creep Rupture Test (hydrostatic resistance test) at 20°C for 100hrs
|
Hydrostatic Pressure Test
|
ISO 4427-2 2019 Table-3 & 4 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
No signs of localized swelling, leakage or weeping and shall not burst during the prescribed test period
|
15
|
Internal Pressure Creep Rupture Test (hydrostatic resistance test) at 80°C for 165hrs
|
Hydrostatic Pressure Test
|
ISO 4427-2 2019 Table-3 & 4 Sampling shall be done as per Clause 9.2 of IS 4984-2016
|
No signs of localized swelling, leakage or weeping and shall not burst during the prescribed test period
|
16
|
Effect on Water
|
-
|
-
|
Not Detected
|
WhatsApp us